AD-310 EC-TDS meter (ADWA) is a professional portable conductivity meter with five ranges and an AD76309 probe. Accuracy ±1%.

ADWA AD-310: a professional portable conductivity meter with an external probe
The AD-310 EC-TDS meter is a professional portable meter of electrical conductivity for water, nutrient solutions and other liquids. It covers the range from 0.01 µS/cm to 199.9 mS/cm in five ranges that you select with the RANGE key. Automatic temperature compensation adjusts the measurement to the sample temperature. The manufacturer's page lists it among the EC/TDS meters, and it is useful for monitoring plant growth and for pool and irrigation water.
The set includes the AD-310 meter, four 1.5 V AA batteries, a calibration liquid and instructions in Slovenian. According to the manufacturer's instructions an AD76309 probe with a built-in temperature sensor (1 m cable) is also supplied, and the calibration liquid is 1413 µS/cm (20 mL).
According to the official ADWA manufacturer's instructions the accuracy is ±1% of full scale, and temperature is measured from −9.9 to 120.0 °C.
How to measure and calibrate
Dip the probe into the sample so that the holes on the sleeve are completely under the surface, tap it to remove air bubbles, select the range with the RANGE key if needed and wait for the reading to settle (the hourglass stops flashing). Rinse the probe thoroughly with deionised water between samples. The meter must be calibrated before measuring. You can also watch the procedure in the measuring video instructions.
Calibration is single-point: dip the probe into a standard solution, press SHIFT and CAL, select the standard value if needed, and when the reading settles press SHIFT and CFM. Str appears on the display and the meter returns to measuring mode. Six standards are stored (84.0 and 1413 µS/cm, and 5.00, 12.88, 80.0 and 111.8 mS/cm), and you can also calibrate with your own value. Calibrate the zero with a dry probe in air. More in the calibration video instructions.
Who is it for
Choose it when you need a meter with several ranges and an external probe that you can replace. For simple pocket measurements see the AD31 EC/TDS meter or the AD32 EC meter, and for a waterproof professional version the AD330/AD332.
Storing and cleaning the probe
Rinse the probe with clean water after measuring. For a more thorough clean, remove the sleeve, wipe the probe with a soft cloth or a non-abrasive cleaner, fit the sleeve back correctly and recalibrate the meter. A replacement A76309 EC/TDS electrode is available separately, and the calibration liquid is the 1.413 mS/cm EC/TDS liquid.
If you are looking for an AD-310 EC-TDS meter for professional conductivity measurement with a replaceable probe and several ranges, this is a portable ADWA meter with ±1% accuracy. Also see all EC and TDS meters.